NORMAL STARTUP
1. Place the unit in the position where it will be run. Do not attempt to lift or move the unit once it is
filled. Damage to the unit or a large spill may occur.
Note: When you decide where to place the unit, make sure there are no obstructions in the way that
will disrupt or block the airflow. Make sure the unit is level at all times. Keep the unit at least three
feet away from walls or other obstructions that will interfere with airflow into the unit.
2. Check to ensure the drain cap is in place and secure.
3. Connect the garden hose to the brass hose adapter. Check that there is a washer in the hose
connection's female end.
4. Open the water supply valve and check that water enters the bottom through the float valve by
removing one cooling pad on the side with the water connection. Allow the unit to fill and check that
the float valve completely shuts off the water.
5. If you are manually filling, remove one or more cooling pads and fill the bottom with a bucket or
hose.
6. Visually monitor the filling operation to avoid overflowing and causing spill damage.
7. Plug the unit into an outlet.
8. Adjust the blower duct to discharge the cool air in the desired direction and tighten the knob on the
end of the threaded rod.
9. Turn the switch to the pump only position and let it run for 5 - 10 minutes to saturate the cooling
pads. Check that the pads are saturated completely and there are no dry spots.
CAUTION: Do not run the pump without water in the bottom or you will damage the pump. Running
the pump dry will void the warranty on the pump.
10. Turn the switch to the High Cool or the Low Cool position to begin normal cooling operation.
NORMAL SHUTDOWN
1. Turn the switch to the High Vent position, and let the unit run until the cooling pads are dry. This will
maximize the life of the pads.
2. Turn the switch to the OFF position. Unplug the unit if you are going to clean the pads or inspect the
components.
3. Shut off the water supply.
4. Drain the bottom if you are going to clean it or store it.
5. If the unit will be stored for the season, ensure the cooling pads are completely dry, and then remove
them. Wrap them in plastic bags or store them in a clean place where they will not be damaged or
get dirty. The unit should be cleaned thoroughly before storing.